Panel PU
Panel PU
Standards Department City on 02/10/2002 and is governedmanagement with quality management system ISO 9001-2008.
Application: Used to build the cold storage, cool storage, supermarkets, clean room, freezing tunnel, where there are strict
requirements on the temperature of 5 ° ÷ -40 ° C
- The standard temperature of the Panel PU
Operating temperature (°C) | Thickness (mm) |
5 | 50 |
5÷ -10 | 80 |
-18 | 100 |
-25 | 120 |
-40 | 150 |
- Specifications:
Stable heat transfer coefficient: 0,018 ÷ 0,020 kcal/m/h/°C
Pull-Compress force : Pn = 1,7 ÷ 2,2 kg/cm²
Bend force : Pu = 40 ÷ 70 kg/cm²
Water absorb coefficient : 1,7 ÷ 2,3 Δp/v%
Endosmosis coefficient : 30 ÷ 60α23°C
Tight rate of cells : 90 ÷ 95%
Ability to endure temperature : -60°C ÷ +80°C
+ Ability to create waves, grooves or flat depending on the requirements of each project
+ Seat assembly between two sheets of PU panel is very tight, very strong, beautiful, high reliability, minimize the heat to escape, ensuring the
necessary cold storage, so significant savings are electricconsumption.
+ Easy to expand premises or off floor
+ Long life (over 20 years), resistant to high temperature (120 ° C)
+ Environmentally friendly, non-toxic, safe to use food container, clean home in the medical field, food processing